Logo  
 中文    

   

  • Home
  • R730CT2-Wireless 2-Gang Thermocouple Interface-T type

Image

Click on above image to view full picture

R730CT2-Wireless 2-Gang Thermocouple Interface-T type

   

This equipment is used to detect temperature of the object and medium which thermocouple is contacted. It can be connected to two thermocouples for testing. It uses SX1276 wireless communication module.

Be the first to review this product

This equipment is used to detect temperature of the object and medium which thermocouple is contacted. It can be connected to two thermocouples for testing. It uses SX1276 wireless communication module.

•Apply SX1276 wireless communication module
•2-cell rechargeable NiMH batteries in series power supply
•Main body protection grade IP65/IP67
•LoRaWAN™ Class A compatible
•Frequency Hopping Spread Spectrum (FHSS)
•Configuration parameters can be configured through a third-party software platform
•Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices / Cayenne
•Low power consumption and long battery life Improved po

Electric:

Power supply

2-cell rechargeable NiMH batteries in series

Operating Voltage

2.3 VDC to 3 VDC

Standy Current

21uA

Transmitting current (max)

130mA @3V

Low Battery Voltage Threshold

2.3V

Solar Panel Specification

5W / 4VDC

NiMH Battery Charging Current

80mA


Frequency:

Frequency Range

863MHz-928MHz 470MHz-510MHz

TX Power

US915 20dbm;
AS923 16dbm;
AU915 20dbm;
CN470 19.15dbm;
EU868 16dbm;
KR920 14dbm;
IN865 20dbm;

Receiving Sensitivity

-136dBm(LoRa,Spreading Factor=12,Bit Rate=293bps );
-121dBm (FSK,Frequency deviation=5kHz, Bit Rate=1.2kbps)

Antenna Type

Built-in antenna

Communication Distance

Up to 10 km
(visible linear obstacle-free transmission distance , actual transmission distance depends on the environment )

Data Transfer Rate

0.3kbps~50kbps

Modulation

LoRa/FSK (Note: You can choose one of them)

Supportable LoRaWAN Band

EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,
IN865-867,CN470-510

(Note: The frequency band is optional and needs to be configured before shipment)


Physical:

Dimension

267.11mmx155mm x208.2mm

Operating Temperature Range

-20℃ to 55℃

Storage Temperature Range

<90% RH (No condensation)

Storage Temperature

-40℃ to 85℃